BMS - 2000 Burner Management System - Download PDF Version
The BMS - 2000 Heater Control is the latest and most powerful burner management system. It is the most flexible, feature packed unit available. Simple operation and configuration are key assets.

The unit features single or dual burner sequencing, first out annunciation for safety interlocks and single or dual temperature control of bath and/or process.
Automatic Sequencing Features
• Single or dual burner control (selectable between in conjunction or independent)
• Auto relite sequence can be de-selected or selected with up to three retry attempts
• Pre and post purge times, auxiliary blower with confirmation and prepurge are configurable
• Dual setpoint thermocouple operation and / or U.V. detection are configurable
• Ignition output signal can be configured as steady or pulsed
• Startup bypass timers are adjustable
• A wide variety of safety interlock devices are configurable into the sequence
• Remote start / stop are configurable
• Configuration is password protected and stored in non-volatile memory
• Auto startup after power failure configurable
• Intermittent pilot or standing pilot configurable
 
Shutdown Annunciation Features
A first out annunciator is built in with direct readout of the shutdown conditions. Each shutdown condition is marked to its
chronological incoming position. The operator must acknowledge each shutdown condition and the condition much be cleared
before startup can be initiated.

Available Standard and Configurable Shutdown Conditions:
• Flame failure on thermocouple
• Flame failure during auto-relite
• Low voltage input
• Bath high temperature
• Remote shutdown
• Low bath level
• Stack high temperature
• Three spare digital input shutdown
• Flame failure on second level
• Local manual shutdown
• Auxiliary flame failure
• Auxiliary bath high temperature
• Low fuel gas pressure
• Purge blower failure
• Spare analog input shutdown
• Thermocouple failure
 
Temperature Controller Features
The controller is available as a single temperature control version or as a dual temperature control version. The dual temperature
control version can be configured so that the controls work completely independent of each other or configured with one controller over-riding the other. Control can be primarily selected between On/Off with adjustable deadband or Proportional with integral and derivative. Deadband and PID parameters are adjustable for tuning and are password protected. The operator can select between auto / manual and remote / local setpoint. Remote temperature indication output and temperature setpoint input are configurable. Bath temperature setpoint and high limit are locally displayed and easily accessible. The status of the temperature control valve is displayed when on / off control is configured. The output percentage is displayed when proportional control is selected.

Specifications
Enclosure Rating CSA Class 1, Div. 2, Nema 4X
CSA (Pending) Class 1, Div. 1 - Intrinsically Safe, Nema 4X
Enclosure Overall Dimensions 10.5" High, 8.5" Width, 6" Depth
Enclosure Construction Molded Fiberglass Polyester - Quick Release Latches
Operating Temperature -40 to +40 Deg. Celsius
Inputs 12 - Digital Solid State, 2 - Analog 4-20 mA
5 - Thermocouple Type "K' Undergrounded Cold Junction Compensated
Outputs 16 - 12-30 VDC - 4 Amp Digital Solid State Optically Isolated
2 - Analog 4-20 mA 500 Ohm Max.
Power Supply 12 to 30 VDC Clean Filtered
Current Draw 80 mA Minimum, 135 mA Typical, 250 mA Maximum
Display Low Temp. LCD - 4 Line, 40 Character Per Line - Heated
Mounting Wall Mount Bracket Standard, 2" Pipe Mount Optional
Communication Digital, Analog and Modbus

The BMS - 2000 Burner Management System Unit is capable of the three main functions required to safely start, monitor and control a single or dual burner gas fired heater. All sequencing, monitoring, control variables and states are fully displayed on a heated backlit LCD display. Full calibration, tuning and configuration are accessible via a password protected front membrane keypad. The unit will carry out, safely and reliably, the complete startup sequence including purge and automatic relite attempts. The safety shutdown interlocks are monitored and in the event of exceeding preset safety levels, the unit will shutdown the burners, first out annunciate the condition and callout. Bath and/or process temperature can be selected with built in three mode controller or on/off controller with adjustable deadband. The operator can select from auto to manual control and from remote to local setpoint.
 
Operation Instructions
To Start:
  1. The operator depresses the "ACK." key to confirm and clear any previous shutdown conditions. The "Clear To Start" flag is displayed.
  2. The operator depresses the "START" key to begin the automatic startup sequence. The "Normal Operation" flag is displayed after the sequence is complete.
To Stop:
  1. The operator can cancel the startup sequence or shutdown the unit safely at anytime by depressing the "STOP" key. The "Local Manual S/D" flag will be displayed.
 
Operator Access to a Wide Selection of Information and Control Parameters by Simply Page Scrolling
 
Page One: • Startup sequence step indication
• First out annunciation with chronological indication
• Pilot flame temperature
Page Three: • Pilot valve status
• Main valve status
• Igniter status
• Purge blower status
Page Two: • Bath and / or process temperature setpoints
• Output level or state
• High temperature protection setting
• Manual / auto indication
• Remote / local indication
Page Four: • Spare analog indication
• Stack temperature and shutdown setpoint
• Supply voltage level
    Page Five: • Temperature control parameters
• Proportional band setting
• Reset value
• Rate value
• On / off control deadband